11 switching frequency changeover, System modules – Lenze ECSCAxxx User Manual

Page 363

Advertising
background image

System modules

MCTRL_MotorControl (node number 131)

Switching frequency changeover

13

l

363

EDBCSXA064 EN 3.2

13.20.11

Switching frequency changeover

For the inverter the following switching frequencies can be set via C0018:

ƒ

4 kHz for power−optimised operation

ð maximum power output of the drive

controller, however, with audible pulse operation.

ƒ

Automatic switch−over between power−optimised and noise optimised operation
(8 kHz).

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0018 fchop

2

Switching frequency

^ 363

1

4 kHz sinus

Power−optimised operation
permanent 4 kHz frequency

2

4 8 kHz sinus

Noise optimised operation
automatic change−over to 8 kHz
at higher load

Automatic switching frequency changeover

You can use the automatic switching frequency changeover if you intend to operate the
drive in the noise optimised range, and if the available torque for acceleration processes
is not sufficient for this purpose.

Condition M = f(I)

Function

M < M

N

(I

N

)

Drive controller operates at 8 kHz (noise optimised)

M

N

(I

N(8)

) < M < M

N

(I

N(4)

)

Drive controller switches to 4 kHz (power−optimised)

M > M

max

(I

max

)

Drive controller operates at 4 kHz in current limitation