System modules, Input frequency = 200 khz – Lenze ECSCAxxx User Manual

Page 334

Advertising
background image

System modules

DFIN_IO_DigitalFrequency (node number 21)
Inputs_DFIN

13

l

334

EDBCSXA064 EN 3.2

13.16.1.1

Configuration master frequency input signal

You configure the type of the master frequency input signal via C0427:

C0427 = 0 (2 phases)

Track

CW rotation

CCW rotation

B

B

A

A

Z

Z

A

Track A leads by 90°
(DFIN_nIn_v = positive
value)

Track A lags by 90°
(DFIN_nIn_v = negative
value)

B

˘

˘

Signal sequence with phase shift (CW
rotation)

C0427 = 1 (A = speed / B = direction)

Track

CW rotation

CCW rotation

B

B

A

A

Z

Z

A

Transmits the speed.

Transmits the speed

B

= FALSE
(DFIN_nIn_v = positive
value)

= TRUE
(DFIN_nIn_v = negative
value)

Control of the direction of rotation via
track B

C0427 = 2 (A or B = speed or direction)

Track

CW rotation

CCW rotation

B

B

A

A

Z

Z

A

Transmits speed and
direction of rotation
(DFIN_nIn_v = positive
value)

= FALSE

B

= FALSE

Transmits speed and
direction of rotation
(DFIN_nIn_v = negative
value)

Control of speed and direction of
rotation via track A or track B

Transfer function

DFIN_nIn_v

+ f [Hz] @

60

Number of incr. from C0420

@ 2

14

15000

Example:

ƒ

Input frequency = 200 kHz

ƒ

C0420 = 2048

DFIN_nIn_v [rpm]

+ 200000 Hz @ 60

2048 +

5859 rpm