10 trip status (dctrl_bexternalfault_b), 11 transfer of the status/control word via aif, System modules – Lenze ECSCAxxx User Manual

Page 329

Advertising
background image

System modules

DCTRL_DriveControl (node number 121)

TRIP status (DCTRL_bExternalFault_b)

13

l

329

EDBCSXA064 EN 3.2

13.15.10

TRIP status (DCTRL_bExternalFault_b)

If "TRIP" is activated in the drive (e.g. via the variable DCTRL_bTripSet_b, C0135/bit 10 or
keypad), the variable DCTRL_bExternalFault_b is set to TRUE.

DCTRL_bExternalFault_b is reset to FALSE, as soon as the error source is reset.

13.15.11

Transfer of the status/control word via AIF

If the control and/or status word of the SB DCTRL_DriveControl is to be assigned to the
SB Inputs_AIF1/Outputs_AIF1, this can be realised in the IEC 1131−3 programming
language AWL, e. g. as follows:

LD DCTRL_wStat
ST AIF1_wDctrlStat /* Writing the status word*/

LD AIF1_wDctrlCtrl
ST DCTRL_wAIF1Ctrl /* Writing the control word*/

)

Note!

The assignment of the bits of the control/status word marked as "not
assigned" depends on the fieldbus module used and the transmission profile
set (z. B. DRIVECOM).

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0135 Control word

0

System control word DCTRL

0

{1}

65535 Controller evaluates information

as 16 bits (binary−coded)

Bit 0

Not assigned

Bit 1

Not assigned

Bit 2

Not assigned

Bit 3

Quick stop (QSP)

Bit 4

Not assigned

Bit 5

Not assigned

Bit 6

Not assigned

Bit 7

Not assigned

Bit 8

Operation inhibit (DISABLE)

Bit 9

Controller inhibit (CINH)

Bit 10

TRIP−SET

Bit 11

TRIP−RESET

Bit 12

Not assigned

Bit 13

Not assigned

Bit 14

Not assigned

Bit 15

Not assigned