1 inputs_dctrl, System modules – Lenze ECSCAxxx User Manual

Page 321

Advertising
background image

System modules

DCTRL_DriveControl (node number 121)

Inputs_DCTRL

13

l

321

EDBCSXA064 EN 3.2

13.15.1

Inputs_DCTRL

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Notes

DCTRL_bFail_b

Bool

Binary

%IX121.0.0

˘

˘

TRUE = active error

DCTRL_bImp_b

%IX121.0.1

TRUE = high−resistance
power output stages

DCTRL_bTrip_b

%IX121.0.2

TRUE = active error

DCTRL_bQspIn_b

%IX121.0.3

TRUE = quick stop (QSP)
(

^ 324)

DCTRL_bRdy_b

%IX121.0.4

TRUE = ready for
operation

DCTRL_bCwCcw_b

%IX121.0.5

FALSE = CW rotation
TRUE = CCW rotation

DCTRL_bNActEq0_b

%IX121.0.6

TRUE = motor
speed < C0019

DCTRL_bCInh_b

%IX121.0.7

TRUE = controller inhibit
(

^ 325)

DCTRL_bStat1_b

Bool

Binary

%IX121.0.8

˘

˘

Status signals (

^ 327)

DCTRL_bStat2_b

%IX121.0.9

DCTRL_bStat4_b

%IX121.0.10

DCTRL_bStat8_b

%IX121.0.11

DCTRL_bWarn_b

Bool

Binary

%IX121.0.12

˘

˘

TRUE = active warning

DCTRL_bMess_b

%IX121.0.13

TRUE = active message

DCTRL_bInit_b

%IX121.0.14

TRUE = initialisation
phase

DCTRL_bExternalFault_b

%IX121.0.15

TRUE = external error
(

^ 329)

DCTRL_wStat

Word

˘

%IW121.1

C0150

hex

Status word (

^ 327)

DCTRL_wFaultNumber

%IW121.2

C0168

Current error number
(

^ 369)