22 system_flags (system flags, node number 151), 1 inputs system_flags, System modules – Lenze ECSCAxxx User Manual

Page 372

Advertising
background image

System modules

SYSTEM_FLAGS (system flags, node number 151)
Inputs SYSTEM_FLAGS

13

l

372

EDBCSXA064 EN 3.2

13.22

SYSTEM_FLAGS (system flags, node number 151)

System flags are global variables that are integrated in the run−time system as an inherent
part. They feature functionalities for making programming easier.

13.22.1

Inputs SYSTEM_FLAGS

The following system flags are part of the ECSxA... axis module:

Variable

Data type

Address

Comments

SYSTEM_bClock01Hz

BOOL

%IX151.0.0

0.1 Hz system clock

SYSTEM_bClock1Hz

%IX151.0.8

1.0 Hz system clock

SYSTEM_bClock10Hz

%IX151.1.0

10 Hz system clock

SYSTEM_bClock0100Hz

%IX151.1.8

100 Hz system clock

SYSTEM_bTogCycleTask

%IX151.2.0

Toggle marker − cyclic task

SYSTEM_b1LoopCyclicTask

%IX151.2.8

First loop − cyclic task

SYSTEM_b1LoopTask2

%IX151.3.0

First loop − task ID2

SYSTEM_b1LoopTask3

%IX151.3.8

First loop − task ID3

SYSTEM_b1LoopTask4

%IX151.4.0

First loop − task ID4

SYSTEM_b1LoopTask5

%IX151.4.8

First loop − task ID5

SYSTEM_b1LoopTask6

%IX151.5.0

First loop − task ID6

SYSTEM_b1LoopTask7

%IX151.5.8

First loop − task ID7

SYSTEM_b1LoopTask8

%IX151.6.0

First loop − task ID8

SYSTEM_b1LoopTask9

%IX151.6.8

First loop − task ID9

SYSTEM_nTaskInterval

integer

%IW151.7

Interval of current task

SYSTEM_nTaskID

%IW151.8

Identification of current task

I

Tip!

The system flags are not generated in simulation mode.

SYSTEM_bClockxHz

These system flags output a fixed clock pulse with an equal pulse/pause ratio.

ƒ

State alterations of the flag are effected in real time.

ƒ

When you use this system flag, observe the sampling frequency used for polling the
flag (aliasing effect). It should at least be twice the change frequency.

Example: You want to use the system flag SYSTEM_bClock100Hz as a clock for a
counter.

ƒ

The pulse/pause ratio is 5 ms/5 ms.

ƒ

To avoid an aliasing effect, the counter must always be polled with an INTERVAL
TASK < 5 ms.

)

Note!

The SYSTEM_bClockxHz system variables must not be used to trigger
event−controlled tasks. Use time−controlled tasks for this.

Advertising