Setting the boot−up time/cycle time

Boot−up time (C0356/1, C2456/1) setting

In a CAN network without higher−level control (PLC), a bus node (boot−up master) has to
initialise the CAN network. If the 24 V low−voltage supply is switched on, the boot−up time
elapses. After the boot−up time has elapsed, the NMT telegram for initialising the CAN
network is sent by the boot−up master and the process data transfer is started.

ƒ

Only valid if C0352/C2452 = 1 (master).

ƒ

Normally the Lenze setting (3000 ms) is sufficient.

ƒ

State change from "Pre−operational" to "Operational"

Cycle time for process output data (C0356/2...3, C2456/2...3)

Transmission cycle time for the process data objects CAN2...3_OUT (C0356/2...3) or
CANaux2...3_OUT (C2456/2...3) in cyclic operation (without sync)

ƒ

Setting "0" = event−controlled data transmission
The output data will only be sent if a value in the output object changes.

Activation delay for process output data (C0356/4, C2456/4)

Delay time for initial transmission of the process data objects CAN2...3_OUT (C0356/4) or
CANaux2...3_OUT (C2456/4) after the CAN bus changes from NMT "Pre−Operational" NMT
state to "Operational"".

After the delay time has elapsed, the process data objects CAN2...3_OUT or
CANaux2...3_OUT will be sent for the first time.

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0356

CAN time settings for CAN bus
interface X4

^ 163

1 CAN times

3000

0

{1 ms}

65000 CAN boot−up time:

Delay time after mains
connection for initialisation
through the master.

2 CAN times

0

CAN2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission

3 CAN times

0

4 CAN times

20

Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"