Appendix

Code table

14

l

385

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C0006] Op mode

1

Operating mode of the motor
control

l

If the master pulse (via
MCTRL: C0911 = 0 or DfIn:
C0428 = 0) is used, the
voltage supply has to be
switched off and then on
again when the operating
mode is changed.

l

Otherwise, the master pulses
will not be recognised.

1

Servo PM−SM

Servo control of synchronous
motors

2

Servo ASM

Servo control of asynchronous
motors

C0009 LECOM

address

1

Entry of the device address for
operation via AIF interface X1

1

{1}

99 Communication modules on AIF

interface X1:

l

LECOM−A/B/LI 2102

l

PROFIBUS−DP 2133

C0011 Nmax

3000

Maximum speed

^ 357

500

{1 rpm}

16000 Reference value for the absolute

and relative setpoint selection
for the acceleration and
deceleration times.
For parameter setting via
interface: greater changes in one
step should only be made when
the controller is inhibited (CINH)!

C0017 FCODE (Qmin)

50

Free code for using speed signals
(Speed signal FCODE_nC17_a)

^ 347

−16000

{1 rpm}

16000

C0018 fchop

2

Switching frequency

1

4 kHz sin

4 kHz permanent PWM
frequency

2

8/4 kHz sin

8 kHz PWM frequency with
automatic derating to 4 kHz at
high load

C0019 Thresh nact =

0

0

Threshold when actual speed
value (n

act

) = 0 is detected.

(DCTRL_bNActEq0_b)

0

{1 rpm}

16000

C0022 Imax current

à

I

max

limit

0

{0.01 A}

à

Device−dependent list

Max. current can be gathered
from the technical data.

C0023 Imax fld.weak

0

Maximum field weakening
current for synchronous
machines

0

{1 %}

100

C0026

Offset for relative analog signals
(AIN)

^ 275

^ 347

1 FCODE(offset)

0,0

−199,99

{0.01 %}

199,99 FCODE_nC26_1_a

2 FCODE(offset)

0,0

FCODE_nC26_2_a