System modules – Lenze ECSCAxxx User Manual

Page 346

Advertising
background image

System modules

DIGITAL_IO (node number 1)
Outputs_DIGITAL (digital outputs)

13

l

346

EDBCSXA064 EN 3.2

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0118

Polarity of the digital outputs

^ 345

^ 129

1 DIGOUT pol

0

HIGH level active

X6/DO1 (DIGOUT_bOut1_b)

2 DIGOUT pol

0

HIGH level active

X25 (DIGOUT_bRelais_b, brake
connection)

0

HIGH level active

1

LOW level active

C0444

Status of the digital outputs
Only display

^ 345

1 DIS: DIGOUT

0

1 Status of the digital output

X6/DO1

2 DIS: DIGOUT

Relay control status

C0602 MONIT REL1

3

Fault response − open circuit
monitoring of relay output X25

0

TRIP

2

Message

3

Off

4

FAIL−QSP

Terminal assignment

Digital
inputs

Function

Electrical data

X6

Digital output

24 V DC
0.7 A (max. 1.4 A)
short−circuit−proof

X6/DO1

Digital output 1

X6

Output "safe torque off" (former "safe standstill")

X6/SO

Output feedback

LOW

During operation

HIGH "Safe torque off" (former

"safe standstill") active

X25

Connection motor holding brake

23 ... 30 V DC;
max. 1.5 A
Set the brake voltage so that the
permissible voltage at the brake
will not be exceeded or the values
do not fall below the threshold!

X25/B1

Brake connection +

X25/B2

Brake connection −

X6

Low−voltage supply motor holding brake

X6/B+

Brake supply +

X6/B−

Brake supply −

Advertising
This manual is related to the following products: