Monitoring functions, Overview of monitoring functions – Lenze ECSCAxxx User Manual

Page 199

Advertising
background image

Monitoring

functions

Overview of monitoring functions

10

l

199

EDBCSXA064

EN 3.2

Possible fault responses

l Lenze setting

ü Can be set

Monitoring

Off

Fail−QSP

Warning

Message

TRIP

Code

Source

Description

Fault message

x126

CE15

Communication error of the gateway function via CAN bus at interface X14
(CAN−AUX)

l

C0371 = 1: Gateway channel X14 (CAN−AUX)

l

C2470: Selection of the CANaux object for L_ParRead and L_ParWrite

CANaux

C2485

ь

ь

l

x260

Err Node
Guard

"Life Guarding Event":
The controller configured as CAN slave does not receive a "Node Guarding"
telegram with the "Node Life Time" from the CAN master.

Node
Guarding

C0384

l

ь

ь

ь

2)

ь

Temperatures / sensors

0050

OH

Device heatsink temperature > 90° C

MCTRL

l

0051

OH1

Temperature inside the device > 90° C

MCTRL

l

x053

OH3

Motor temperature > 150° C

MCTRL

C0583

l

ь

ь

x054

OH4

Heatsink temperature > C0122

MCTRL

C0582

ü

l

ü

x055

OH5

Temperature inside the device > C0124

MCTRL

C0605

ü

l

ü

x057

OH7

Motor temperature > C0121

MCTRL

C0584

ü

l

ü

x058

OH8

Motor temperature via inputs T1 and T2 is too high.

MCTRL

C0585

ü

l

ü

x086

Sd6

Thermal sensor error on the motor (X7 or X8)

MCTRL

C0594

ь

ь

l

x095

FAN1

Devicefan monitoring (only for built−in units)

ü

l

x110

H10

Device thermal sensor error on heatsink

FWM

C0588

l

ü

x111

H11

Device thermal sensor error in the interior of the device

FWM

C0588

l

ü

Motor / feedback system

0011

OC1

Short circuit of motor cable

MCTRL

l

0012

OC2

Motor cable earth fault

MCTRL

l

0015

OC5

Device utilisation I x t (fix 100%)

MCTRL

l

0016

OC6

Motor utilisation I

2

x t (threshold C0120)

MCTRL

l

x017

OC7

Device utilisation I x t (clip C0123)

MCTRL

C0604

ü

l

ü

x018

OC8

Motor utilisation I

2

x t (threshold C0127)

MCTRL

C0606

ü

l

ü

x032

LP1

Motor phase failure
Note: Can only be used for asynchronous motors. Activation of the motor
phase failure detection minimises the computing time available to the
user!

MCTRL

C0597

ь

ь

l

x081

Rel1

Open circuit monitoring of the brake relay output (X25)

FWM

C0602

ь

ь

ь

l

x082

Sd2

Resolver error at X7
Note: If monitoring is switched off or in the case of "Warning", the machine
can reach very high speeds in the case of fault, which may result in the
damage of the motor and the machine that is driven!

MCTRL

C0586

l

ь

ь

x: 0 = TRIP, 1 = message, 2 = warning, 3 = FAIL−QSP

1)

Adjustable in the DDS under Project

W Exceptional handling

2)

For ECSxA... only

Advertising