1 inputs_mctrl, System modules, Mctrl_motorcontrol (node number 131) inputs_mctrl – Lenze ECSCAxxx User Manual

Page 352: 1 inputs_mctrl system variables

Advertising
background image

System modules

MCTRL_MotorControl (node number 131)
Inputs_MCTRL

13

l

352

EDBCSXA064 EN 3.2

13.20.1

Inputs_MCTRL

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Comments

MCTRL_bQspIn_b

BOOL

binary

%IX131.0.0.0

C0042

bin

TRUE = drive carries out
quick stop (QSP)

MCTRL_nNSetIn_a

integer

analog

%IW131.1

C0050

dec [%]

Speed setpoint

l

16384

º 100 % n

max

(C0011)

MCTRL_bMMax_b

BOOL

binary

%IX131.0.2

˘

˘

TRUE = speed controller
operates in limitation

MCTRL_nMSetIn_a

integer

analog

%IW131.3

C0056

dec [%]

Torque setpoint

l

16384

º 100 % M

max

(C0057)

MCTRL_bIMax_b

BOOL

binary

%IX131.0.1

˘

˘

TRUE = drive operates at
limit C0022

MCTRL_nIAct_a

integer

analog

%IW131.5

˘

˘

Actual motor current

l

16384

º 100 % I

max

(C0022)

MCTRL_nDCVolt_a

%IW131.6

DC voltage

l

16384

º 1000 V

MCTRL_nMAct_a

%IW131.4

Current torque

l

16384

º 100 % M

max

(C0057)

MCTRL_wMmaxC57

Word

˘

%IW131.16

˘

˘

Display of maximum
torque (C0057) x 10

MCTRL_bUnderVoltage_
b

BOOL

binary

%IX131.0.3

˘

˘

Monit: undervoltage

MCTRL_bOverVoltage_b

%IX131.0.4

Monit: overvoltage

MCTRL_bShortCircuit_b

%IX131.0.5

Monit: short circuit

MCTRL_bEarthFault_b

%IX131.0.6

Monit: earth fault

MCTRL_bIxtOverload_b

%IX131.9.2

Monit: I x t − overload

MCTRL_nPos_a

integer

analog

%IW131.7

˘

˘

Actual phase value as
analog signal

l

90°

º 100%

MCTRL_nNAct_v

integer

Velocity

%IW131.8

˘

˘

Actual speed value
[inc/ms]

MCTRL_nNAct_a

integer

analog

%IW131.2

˘

˘

Actual speed value

l

16384

º 100 % n

max

(C0011)

MCTRL_dnPos_p

double

integer

position

%ID131.5

˘

˘

Rotor position of the
motor

MCTRL_bNmaxFault_b

BOOL

binary

%IX131.0.7

˘

˘

Monit: max. system
speed exceeded

MCTRL_nNmaxC11

integer

˘

%IW131.15

˘

˘

Display of max. speed
(C0011)

MCTRL_bActTPReceived_
b

BOOL

binary

%IX131.0.10

˘

˘

Receive touch probe (TP)

MCTRL_dnActIncLastScan
_p

double

integer

position

%ID131.6

˘

˘

Dinc during TP and task
start

Advertising
This manual is related to the following products: