System modules – Lenze ECSCAxxx User Manual

Page 290

Advertising
background image

System modules

CAN2_IO (node number 32)

13

l

290

EDBCSXA064 EN 3.2

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0356

CAN time settings for CAN bus
interface X4

^ 163

1 CAN times

3000

0

{1 ms}

65000 CAN boot−up time:

Delay time after mains
connection for initialisation
through the master.

2 CAN times

0

CAN2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission

3 CAN times

0

4 CAN times

20

Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"

C0357

Monitoring time for CAN1...3_IN
(CAN bus interface X4)

^ 202

1 CE monit time

3000

1

{1 ms}

65000 CE1 monitoring time

2 CE monit time

3000

CE2 monitoring time

3 CE monit time

3000

CE3 monitoring time

C0863

Digital process data input words
for CAN bus interface X4
Hexadecimal value is bit−coded.
Read only

^ 446

0000

{hex}

FFFF

1 CAN IN bits

Bit 0

...

Bit15 CAN1_IN: Process data input

word 1

2 CAN IN bits

Bit 16

...

Bit 31 CAN1_IN: Process data input

word 2

3 CAN IN bits

Bit 0

...

Bit15 CAN2_IN: Process data input

word 1

4 CAN IN bits

Bit 16

...

Bit 31 CAN2_IN: Process data input

word 2

5 CAN IN bits

Bit 0

...

Bit15 CAN3_IN: Process data input

word 1

6 CAN IN bits

Bit 16

...

Bit 31 CAN3_IN: Process data input

word 2

C0866

Analog process data input words
(decimal) for CAN bus interface
X4
100.00% = 16384
Read only

^ 446

1 CAN IN words

−199.99

{0.01 %}

199.99 CAN1_IN word 1

2 CAN IN words

CAN1_IN word 2

3 CAN IN words

CAN1_IN word 3

4 CAN IN words

CAN2_IN word 1

5 CAN IN words

CAN2_IN word 2

6 CAN IN words

CAN2_IN word 3

7 CAN IN words

CAN2_IN word 4

8 CAN IN words

CAN3_IN word 1

9 CAN IN words

CAN3_IN word 2

10 CAN IN words

CAN3_IN word 3

11 CAN IN words

CAN3_IN word 4

Advertising
This manual is related to the following products: