System modules

CAN3_IO (node number 33)

Inputs_CAN3

13

l

297

EDBCSXA064 EN 3.2

13.10.1

Inputs_CAN3

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Comments

CAN3_nInW1_a

integer

analog

%IW33.0

C0866/8

dec [%]

CAN3_nInW2_a

%IW33.1

C0866/9

CAN3_bInB0_b

BOOL

binary

%IX33.0.0

hex

...

...

C0863/5

CAN3_bInB15_b

%IX33.0.15

CAN3_bInB16_b

%IX33.1.0

...

...

C0863/6

CAN3_bInB31_b

%IX33.1.15

CAN3_dnInD1_p

double

integer

position

%ID33.0

C0867/3

dec [inc]

CAN3_nInW3_a

integer

analog

%IW33.2

C0866/10

dec [%]

CAN3_nInW4_a

%IW33.3

C0866/11

User data

The first 4 bytes from the 8 bytes of received user data are assigned to several variables of
different data types. According to requirements, they thus can be evaluated by the PLC
program as:

ƒ

binary information (1 bit)

ƒ

quasi−analog value (16 bit)

ƒ

angle information (32 bit)

Byte

Variable (1 bit)

Variable (16 bit)

Variable (32 bit)

1, 2

CAN3_bInB0_b

...

CAN3_bInB15_b

CAN3_nInW1_a

CAN3_dnInD1_p

3, 4

CAN3_bInB16_b

...

CAN3_bInB31_b

CAN3_nInW2_a

5, 6

CAN3_nInW3_a

7, 8

CAN3_nInW4_a