Appendix, Code table – Lenze ECSCAxxx User Manual

Page 388

Advertising
background image

Appendix

Code table

14

l

388

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0061 Heatsink

temp

Heatsink temperature
Read only

^ 208

−200

{1

°C}

200

C0062 Interior temp

Interior device temperature
Read only

^ 209

−200

{1

°C}

200

C0063 Mot temp

Motor temperature
Read only

^ 206

0

{1

°C}

200

C0064 Utilization

Device utilisation (I x t) over the
last 180 s
Only display

0

{1 %}

150

l

C0064 > 100 % activates
OC5−TRIP.

l

TRIP−RESET only is possible if
C0064 < 95 %.

C0065 U24 ext

External low−voltage supply
(U

24

)

Read only

0,0

{0.1V}

100,0

C0066 Motor load

Thermal motor load I

2x

t

Only display

^ 214

0

{1 %}

250

C0067 Act trip

Current fault (TRIP)
(in case of FAIL−QSP, warning and
message, "0" is displayed.)
Only display

^ 242

C0070 Vp speedCTRL

3.0

Proportional gain of speed
controller (V

pn

)

^ 141

0.00

{ 0.01}

127.99

C0071 Tn speedCTRL

24.0

Reset time − speed controller
(T

nn

)

^ 141

1.0

{0.5 ms}

6000.0

C0072 Td speedCTRL

0.0

Derivative gain of speed
controller (T

dn

)

^ 141

0.0

{0.1 ms}

32.0

C0074 Dynamics

0

Pilot control of the current
controller for higher dynamics

^ 136

0

Normal

1

Enhanced

C0075 Vp currCTRL

20.0

Proportional gain of current
controller (V

pi

)

The upper limit is
device−dependent.

^ 136

0.00

{0.01

W}

381.80 ECSxS/P/M/A004

190.90 ECSxS/P/M/A008

95.46 ECSxS/P/M/A016

47.72 ECSxS/P/M/A032

31.82 ECSxS/P/M/A048

23.86 ECSxS/P/M/A064

Advertising
This manual is related to the following products: