Troubleshooting and fault elimination

Fault messages
Overview of fault messages, error sources and responses

12

l

244

EDBCSXA064 EN 3.2

System error message

Possible settings/response

· Lenze setting

ü Setting possible

Available in

No.

Display

Source

Meaning

Code

TRIP

Messa

ge

Warni

ng

FAIL−Q

SP

Off

Drive

PLC

Servo

PLC

ECSxA

x122 CE11

FIF−CAN
1

FIF−CAN1_IN (monitoring
time can be set with
C2457/1)

C0591

ь

ь

·

ь

CAN−au
x1

CANaux1_IN (monitoring
time can be set with
C2457/1)

C2481

ь

ь

·

ь

x123 CE12

FIF−CAN
2

FIF−CAN2_IN (monitoring
time can be set with
C2457/2)

C0592

ь

ь

·

ь

CAN−au
x2

CANaux2_IN (monitoring
time can be set with
C2457/2)

C2482

ь

ь

·

ь

x124 CE13

FIF−CAN
3

FIF−CAN3_IN (monitoring
time can be set with
C2457/3)

C0593

ь

ь

·

ь

CAN−au
x3

CANaux3_IN (monitoring
time can be set with
C2457/3)

C2483

ь

ь

·

ь

x125 CE14

FIF−CAN BUS−OFF status of FIF−CAN

(too many faulty telegrams
received)

C0595

ь

ь

·

ь

CAN−au
x

BUS−OFF state CAN AUX
(too many faulty telegrams
received)

C2484

ь

ь

·

ь

x126 CE15

CAN−au
x

Communication error of
gateway function (C0370,
C0371) via CAN−AUX

C2485

ь

ь

·

ь

x190 nErr

MCTRL

Speed beyond tolerance
margin (C0576)

C0579

ь

ь

ь

ь

·

ь

ь

x200 NMAX

MCTRL

Maximum speed exceeded
(C0596)

·

ь

ь

x201 overrun Task1

Internal Task with ID 2

2)

·

ь

ь

ь

ь

ь

x202 overrun Task2

Task with ID 3

x203 overrun Task3

Task with ID 4

x204 overrun Task4

Task with ID 5

x205 overrun Task5

Task with ID 6

x206 overrun Task6

Task with ID 7

x207 overrun Task7

Task with ID 8

x208 overrun Task8

Task with ID 9

x219 overrun Cycl.−T Internal Time−out in cyclic task

(PLC_PRG, ID 1)

2)

·

ь

ь

ь

ь

ь

x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP