System modules – Lenze ECSCAxxx User Manual

Page 308

Advertising
background image

System modules

CANaux1_IO (node number 34)
Outputs_CANaux1

13

l

308

EDBCSXA064 EN 3.2

User data

The 8 bytes of user data to be sent can be written via several variables of different data
types. According to requirements, data can therefore be transferred from the PLC program
as

ƒ

binary information (1 bit)

ƒ

status word/quasi−analog value (16 bit)

ƒ

angle information (32 bit)

Byte

Variable (1 bit)

Variable (16 bit)

Variable (32 bit)

1, 2

CANaux1_bFDO0_b

...

CANaux1_bFDO15_b

CANaux1_nOutW0_a

3, 4

CANaux1_bFDO16_b

...

CANaux1_bFDO31_b

CANaux1_nOutW1_a

5, 6

CANaux1_bFDO32_b

...

CANaux1_bFDO47_b

CANaux1_nOutW2_a

CANaux1_dnOutD1_p

7, 8

CANaux1_bFDO48_b

...

CANaux1_bFDO63_b

CANaux1_nOutW3_a

)

Note!

Avoid simultaneous overwriting via different variable types to ensure data
consistency.
If you want to describe e.g. the bytes 5 and 6, either use only the variable
CANaux1_dnOutD1_p, only the variable CANaux1_nOutW2_a or only the
variables CANaux1_bFDO32_b ... CANaux1_bFDO47_b!

Advertising