Aif interface (x1) configuration – Lenze ECSCAxxx User Manual

Page 189

Advertising
background image

AIF interface (X1) configuration

Cycle time (XCAN1_OUT ... XCAN3_OUT)

9

l

189

EDBCSXA064 EN 3.2

Code for activating the transmission of event−controlled PDOs

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/ap
pl.

Selection

C2364

0

Event−controlled PDO
transmission
(AIF interface X1)

0

Send PDOs when changing to
"Operational" state

1

Do not send PDOs

Code for enabling the second parameter data channel and the PDO channels

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/ap
pl.

Selection

C2365

Enabling the second parameter
data channel and the PDO
channels
(AIF interface X1)

1

0

0

{1}

3 Enabling the second parameter

data channel

2

1

Enabling the first process data
channel

3

1

Enabling the second process data
channel

4

1

Enabling the third process data
channel

0

Deactivated

1

Activated

2

Reception activated

3

Transmission activated

Advertising
This manual is related to the following products: