2 outputs_digital (digital outputs), System modules, System variables – Lenze ECSCAxxx User Manual

Page 345

Advertising
background image

System modules

DIGITAL_IO (node number 1)

Outputs_DIGITAL (digital outputs)

13

l

345

EDBCSXA064 EN 3.2

13.18.2

Outputs_DIGITAL (digital outputs)

This SB conditions the digital signal DIGOUT_bOut1_b and outputs it via X6/DO1.

ƒ

A motor holding brake supplied with low voltage via X6/B+ and X6/B− can be
connected to X25/B1 and X25/B2:
– The motor holding brake can be switched by the signal DIGOUT_bRelais_b.
– The terminal polarity for the outputs X6/DO1, X25/B1 and X25/B2 can be

configured via C0118.

ƒ

X6/SO serves to the feedback of the safety function "safe torque off" (former "safe
standstill").

Outputs_DIGITAL

X6

X6

1

0

C0118/1

DO1

SO

1

B-

B2

B+

1

0

C0118/2

1

B1

X25

X6

safe torque off

C0444/1

C0444/2

C0602

MONIT-Rel1

DIGOUT_bOut1_b

DIGOUT_bRelais_b

ECSXA242

Fig. 13−27

System block "Outputs_DIGITAL"

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Notes

DIGOUT_bOut1_b

BOOL

Binary

%QX1.0.0

C0444/1

bin

DIGOUT_bRelais_b

%QX1.0.1

C0444/2

Feedback "safe torque
off" (former "safe
standstill")

Advertising
This manual is related to the following products: