9 quick stop (qsp), System modules – Lenze ECSCAxxx User Manual

Page 361

Advertising
background image

System modules

MCTRL_MotorControl (node number 131)

Quick stop (QSP)

13

l

361

EDBCSXA064 EN 3.2

13.20.9

Quick stop (QSP)

The QSP function serves to stop the drive ˘ irrespective of the setpoint selection ˘ within
the time set in C0105.

ƒ

The QSP function is active if MCTRL_bQsp_b is set = TRUE.

ƒ

If the SB DCTRL_DriveControl is to actuate QSP (see also

^ 361), program the QSP

function as follows:

MCTRL_bQspOut_b

MCTRL_bNMSwt_b

MCTRL_nLoMLim_a

MCTRL_nHiMLim_a

C0907/3

C0906/4

C0906/3

C0907/2

OR

DCTRL_bQspIn_b

Any Variable

ECSXA267

Fig. 13−30

Programming: actuation of a quick stop (QSP) via SB "Inputs_DCTRL"

Function:

ƒ

The torque limitation MCTRL_nLoMLim_a and MCTRL_nHiMLim_a is switched
inactively, i. e. the process is run at

±100 % capacity (¶ 356). The drive is operated by

the speed controller.

ƒ

The phase controller is switched actively. If the rotor position is moved actively, the
drive creates a torque to counter the swing if
– C0254 is set unequal to ’0’.
– MCTRL_nPosLim_ais controlled by means of a value > 0 %.

ƒ

The speed is reduced to ’0’ within the deceleration time set via C0105:

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0105 QSP Tif

0.0

Deceleration time for quick stop
(QSP)

^ 361

0.000

{0.001 s}

999.999 Relating to speed variation n

max

(C0011) ...0 rev./min.

Advertising