Commissioning

Operation with motors from other manufacturers
Entering motor data manually

6

l

132

EDBCSXA064 EN 3.2

6.12

Operation with motors from other manufacturers

6.12.1

Entering motor data manually

If you use motors of other manufacturers together with the ECS axis module, you have to
enter the motor data manually. The GDC includes the required codes in the parameter
menu under Motor/feedback systems

W W Motor adjustment.

Fig. 6−9

GDC view: Manual setting of the motor data

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

[C0006] Op mode

1

Operating mode of the motor
control

l

If the master pulse (via
MCTRL: C0911 = 0 or DfIn:
C0428 = 0) is used, the
voltage supply has to be
switched off and then on
again when the operating
mode is changed.

l

Otherwise, the master pulses
will not be recognised.

1

Servo PM−SM

Servo control of synchronous
motors

2

Servo ASM

Servo control of asynchronous
motors

C0018 fchop

2

Switching frequency

1

4 kHz sin

4 kHz permanent PWM
frequency

2

8/4 kHz sin

8 kHz PWM frequency with
automatic derating to 4 kHz at
high load

C0022 Imax current

à

I

max

limit

0

{0.01 A}

à

Device−dependent list

Max. current can be gathered
from the technical data.