System modules – Lenze ECSCAxxx User Manual

Page 336

Advertising
background image

System modules

DFIN_IO_DigitalFrequency (node number 21)
Inputs_DFIN

13

l

336

EDBCSXA064 EN 3.2

13.16.1.2

Configurating touch probe

Process

If an edge change on the input actuating a TP (e. g. X6/DI1) occurs, the instantaneous
phase value (master frequency input value) is stored in the operating system by means of
a very fast interrupt.

DFIN_dnIncLastScan_p

TP



j

Fig. 13−24

Function diagram of a Touch Probe (TP)



Time−equidistant start of an interval task

J

Phase−angle signal

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0428 DFIN TP sel.

0

DFIN touch probe signal source

^ 336

^ 331

0

Zero pulse of position encoder (C0490) X7/X8

1

Touch probe input TP1

X6/DI1

2

Zero pulse of digital frequency input

X8

C0429 TP1 delay

0

DFIN dead time compensation
TP1 (DI1)

^ 336

^ 331

−32767

{1 inc}

32767

C0431 DFIN TP Edge

0

DFIN touch probe TP1 edge
(for touch probe via digital input
X6/DI1 (C0428 = 1))

^ 336

0

Rising edge TP1

1

Falling edge TP1

2

Rising and falling edge TP1

3

Switched off

Advertising