Appendix

Code table

14

l

414

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0603 MONIT CE5

3

Fault response − gateway
function monitoring (CE5)
"Timeout" when remote
parameter setting (C0370) is
activated via interface X4 (CAN)

^ 202

^ 180

0

TRIP

2

Warning

3

Off

C0604 MONIT OC7

2

Fault response − monitoring of
Ixt device utilisation.
Ixt threshold can be set under
C0123.

^ 205

0

TRIP

2

Warning

3

Off

C0605 MONIT OH5

2

Fault response − monitoring of
temperature inside the
controller.
Temperature threshold can be
set under C0124.

^ 209

0

TRIP

2

Warning

3

Off

C0606 MONIT OC8

2

Fault response − monitoring of
I

2

x t motor utilisation.

Threshold can be set under
C0120.

^ 214

0

TRIP

2

Warning

3

Off

C0607 MONIT NMAX

0

Fault response − maximum speed
monitoring of the machine

0

TRIP

2

Warning

3

Off

C0608 ovr. Tx−Queue

2

Fault response − transmission
memory overflow of free CAN
objects

0

TRIP

1

Message

2

Warning

3

Off

4

FAIL−QSP

C0609 ovr. Rx−Isr

0

Fault response Receive memory
overflow of free CAN objects

0

TRIP

4

FAIL−QSP