6 setting trip (trip-set), 7 resetting trip (trip-reset), 6 setting trip (trip−set) – Lenze ECSCAxxx User Manual

Page 326: 7 resetting trip (trip−reset), System modules

Advertising
background image

System modules

DCTRL_DriveControl (node number 121)
Setting TRIP (TRIP−SET)

13

l

326

EDBCSXA064 EN 3.2

13.15.6

Setting TRIP (TRIP−SET)

This function sets "TRIP" in the drive and reports "external error" (error message "EEr").

ƒ

The function can be controlled via the following inputs (OR’d):
– Control word DCTRL_wAIF1Ctrl (

259)

– Control word DCTRL_wCAN1Ctrl (

283)

– Control word C0135, bit 10
– Variable DCTRL_bTripSet_b (TRUE = set TRIP)

ƒ

C0136/1 indicates the control word C0135.

ƒ

The reaction to TRIP can be set via C0581:

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0581 MONIT EEr

0

Fault response − external fault
monitoring "ExternalFault" (EEr)

^ 326

0

TRIP

1

Message

2

Warning

3

Off

4

FAIL−QSP

13.15.7

Resetting TRIP (TRIP−RESET)

This function resets an upcoming TRIP if the cause of malfunction is eliminated. If the cause
of malfunction is still active, no response will be effected.

ƒ

The function can be controlled via the following inputs (OR’d):
– Control word DCTRL_wAIF1Ctrl (

259)

– Control word DCTRL_wCAN1Ctrl (

283)

– Control word C0135, bit 11
– Variable DCTRL_bTripReset_b
– Code C0043

ƒ

C0136/1 indicates the control word C0135.

)

Note!

The function is only carried out by a FALSE−TRUE edge of the signal resulting
from the OR operation.
If one input is assigned to TRUE, a FALSE−TRUE edge cannot occur.