System modules

CANaux3_IO (node number 36)

Inputs_CANaux3

13

l

317

EDBCSXA064 EN 3.2

13.14.1

Inputs_CANaux3

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Comments

CANaux3_nInW1_a

integer

analog

%IW36.0

C2492/8

dec [%]

CANaux3_nInW2_a

%IW36.1

C2492/9

CANaux3_bInB0_b

BOOL

Binary

%IX36.0.0

hex

...

...

C2491/5

CANaux3_bInB15_b

%IX36.0.15

CANaux3_bInB16_b

%IX36.1.0

...

...

C2491/6

CANaux3_bInB31_b

%IX36.1.15

CANaux3_dnInD1_p

Double
integer

Position

%ID36.0

˘

˘

CANaux3_nInW3_a

integer

analog

%IW36.2

C2492/10

dec [%]

CANaux3_nInW4_a

%IW36.3

C2492/11

User data

The first 4 bytes from the 8 bytes of received user data are assigned to several variables of
different data types. According to requirements, they thus can be evaluated by the PLC
program as:

ƒ

binary information (1 bit)

ƒ

quasi−analog value (16 bit)

ƒ

angle information (32 bit)

Byte

Variable (1 bit)

Variable (16 bit)

Variable (32 bit)

1, 2

CANaux3_bInB0_b

...

CANaux3_bInB15_b

CANaux3_nInW1_a

CANaux3_dnInD1_p

3, 4

CANaux3_bInB16_b

...

CANaux3_bInB31_b

CANaux3_nInW2_a

5, 6

CANaux3_nInW3_a

7, 8

CANaux3_nInW4_a