Appendix – Lenze ECSCAxxx User Manual

Page 423

Advertising
background image

Appendix

Code table

14

l

423

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C2370

XCAN Heartbeat time setting
(AIF interface X1)

1

0

0

{1 ms}

65535 Consumer heartbeat time

2

0

0

{1 ms}

65535 Producer heartbeat time

C2371

128

XCAN COB−ID Emergency Object
(AIF interface X1)

0

{1}

2047

C2372

0

XCAN COB−ID Emergency Object
(AIF interface X1)

0

{1}

65535 Inhibit time emergency

C2373

XCAN Sync counter
(AIF interface X1)

1 Sync Rate IN

1

1

{1}

240 XCAN1_IN

2 Sync Rate IN

1

XCAN2_IN

3 Sync Rate IN

1

XCAN3_IN

C2374

XCAN Sync counter
(AIF interface X1)

1 Sync Rate OUT

1

1

{1}

240 XCAN1_OUT

2 Sync Rate OUT

1

XCAN2_OUT

3 Sync Rate OUT

1

XCAN3_OUT

C2375

TX mode for XCANx_OUT
(AIF interface X1)

1 XCAN Tx

mode

0

Response to sync

XCAN1_OUT

2 XCAN Tx

mode

0

Response to sync

XCAN2_OUT

3 XCAN Tx

mode

0

Response to sync

XCAN3_OUT

0

Response to sync

1

No response to sync

2

Event

3

Event, cycle C2356 superimposed

C2376

XCAN1_OUT mask
(AIF interface X1)

1 XCAN1 Mask

FFFF

0000

{hex}

FFFF Mask for process data output

word 1

2 XCAN1 Mask

FFFF

Mask for process data output
word 2

3 XCAN1 Mask

FFFF

Mask for process data output
word 3

4 XCAN1 Mask

FFFF

Mask for process data output
word 4

Advertising