System modules – Lenze ECSCAxxx User Manual

Page 310

Advertising
background image

System modules

CANaux2_IO (node number 35)

13

l

310

EDBCSXA064 EN 3.2

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C2456

CAN time settings for CAN bus
interface X14 (CAN−AUX)

^ 163

1 CANa times

3000

0

{1 ms}

65000 CAN−AUX boot−up time:

Delay time after mains
connection for initialisation
through the master.

2 CANa times

0

CANaux2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission

3 CANa times

0

4 CANa times

20

Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"

C2457

Monitoring time for
CANaux1...3_IN (CAN bus
interface X14)

^ 202

1 CE monit time

3000

1

{1 ms}

65000 CE11 monitoring time

2 CE monit time

3000

CE12 monitoring time

3 CE monit time

3000

CE13 monitoring time

C2491

Process data input words
(hexadecimal) for CAN bus
interface X14
Hexadecimal value is bit−coded.
Read only

1 CANa IN bits

0

{1 hex}

FFFF CANaux1_IN (bit 0 ... 15)

2 CANa IN bits

CANaux1_IN (bit 16 ... 31)

3 CANa IN bits

CANaux2_IN (bit 0 ... 15)

4 CANa IN bits

CANaux2_IN (bit 16 ... 31)

5 CANa IN bits

CANaux3_IN (bit 0 ... 15)

6 CANa IN bits

CANaux3_IN (bit 16 ... 31)

Advertising