System modules – Lenze ECSCAxxx User Manual

Page 367

Advertising
background image

System modules

MCTRL_MotorControl (node number 131)

Adjusting the motor data

13

l

367

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0083 DIS:Tr

Rotor time constant of the
asynchronous motor
Read only

0.00

{0.01 ms}

327.67

[C0084] Mot Rs

1.10

Stator resistance of the motor
The upper limit is
device−dependent.

0.00

{0.01

W}

95.44 ECSxS/P/M/A004

47.72 ECSxS/P/M/A008

23.86 ECSxS/P/M/A016

11.93 ECSxS/P/M/A032

7.95 ECSxS/P/M/A048

5.96 ECSxS/P/M/A064

[C0085] Mot Ls

5.30

Leakage inductance of the motor

0.00

{0.01 mH}

200.00

[C0087] Mot speed

3700

Rated motor speed

300

{1 rpm}

16000

[C0088] Mot current

7.0

Rated motor current

0.5

{0.1 A}

500.0

[C0089] Mot

frequency

185

Rated motor frequency

10

{1 Hz}

1000

[C0090] Mot voltage

325

Rated motor voltage

50

{1 V}

500

[C0091] Mot cos phi

1.0

cos

j of the asynchronous motor

0.50

{0.01}

1.00

C0092 DIS:Isdeff

Magnetising current of the
asynchronous motor
Read only

0.00

{0.01 A}

327,67

C0093 Drive ident

Device identification of the ECS
axis module
Read only

0

Defective power section

1

No power section recognised

4

ECSxS/P/M/A004C4

8

ECSxS/P/M/A008C4

16

ECSxS/P/M/A016C4

32

ECSxS/P/M/A032C4

48

ECSxS/P/M/A048C4

64

ECSxS/P/M/A064C4

65

ECSxS/P/M/A064C2

[C0095] Rotor pos adj

0

Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).

^ 138

0

Inactive

1

Active

Advertising