Appendix

Memories
Retain memory

14

l

376

EDBCSXA064 EN 3.2

14.3

Memories

The table below gives you an overview of the memories available:

Memory

Size

Information

ROM

Program memory

512 kbytes

Re−written whenever the program is downloaded

RAM

PLC data memory

10 kbytes

Can be symbolically used for FB instances and PLC variables.

Application memory

2 blocks

à 64 kbytes

Data get lost after mains disconnection.

E2PROM−buffered memory

Retain memory

160 bytes

See chapter 14.3.1

Persistent memory

32 bytes

See chapter 14.3.2

I

Tip!

Function library LenzeMemDrv.lib includes functions for read/write access to
the additional backup memory (application data memory) of the ECSxA... axis
module.

,

Further information ...

can be found in the Manual for the function library LenzeMemDrv.lib.

14.3.1

Retain memory

The values of the retain variables are stored fail−safe in the retain memory, and therefore
are still available to the program after mains switching. Saving with C0003 = 1 is not
necessary.

ƒ

Retain variables are declared by using the variable class

VAR RETAIN.

ƒ

Retain variables are created as a symbolically addressable memory.

ƒ

At every program download, the retain variables are reset to their initialisation
value; if no initialisation value is specified, the respective retain variable is initialised
with the value ’0’.

ƒ

The retain variables in the ECSxA... axis module can be reset to their initialisation
value in the online mode of the DDS by using the commands Online

W

Reset (cold) or

Online

W

Reset (original).