Appendix – Lenze ECSCAxxx User Manual

Page 412

Advertising
background image

Appendix

Code table

14

l

412

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0582 MONIT OH4

2

Setting of the fault response −
monitoring of heatsink
temperature in C0122

^ 208

0

TRIP

2

Warning

3

Off

C0583 MONIT OH3

0

Fault response − monitoring of
motor temperature (fixed
temperature threshold).
Detection through KTY thermal
sensor via resolver input X7 or
encoder input X8.

^ 206

0

TRIP

2

Warning

3

Off

C0584 MONIT OH7

2

Fault response − motor
temperature monitoring
Temperature threshold can be
set under C0121.
Detection through KTY thermal
sensor via resolver input X7 or
encoder input X8.
Only effective if OH3 is switched
on under C0583.

^ 206

0

TRIP

2

Warning

3

Off

C0586 MONIT SD2

0

Fault response − monitoring
Resolver "ResolverFault" (Sd2)

^ 222

0

TRIP

2

Warning

3

Off

C0588 MONIT

H10/H11

0

Fault response − monitoring
Thermal sensors in the
controller.
H10: Sensor inside the device
H11: Heatsink sensor

^ 210

0

TRIP

2

Warning

3

Off

C0591 MONIT CE1

3

Fault response − monitoring
CAN1_IN (no telegrams)
"CommErrCANIN1" (CE1)

^ 202

0

TRIP

2

Warning

3

Off

C0592 MONIT CE2

3

Fault response − monitoring
CAN2_IN (no telegrams)
"CommErrCANIN2" (CE2)

^ 202

0

TRIP

2

Warning

3

Off