1 inputs_can_management, 2 outputs_can_management, Inputs_can_management – Lenze ECSCAxxx User Manual

Page 278: Outputs_can_management, System modules

Advertising
background image

System modules

CAN_Management (node number 101)
Inputs_CAN_Management

13

l

278

EDBCSXA064 EN 3.2

13.6.1

Inputs_CAN_Management

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Comments

CAN_bCe1CommErrCanI
n1_b

BOOL

binary

%IX101.0.0

˘

˘

CAN1_IN
communication error

CAN_bCe2CommErrCanI
n1_b

%IX101.0.1

CAN2_IN
communication error

CAN_bCe3CommErrCanI
n1_b

%IX101.0.2

CAN3_IN
communication error

CAN_bCe4BusOffState_
b

%IX101.0.3

CAN bus "Off State"
detected (CAN bus
interface X4)

CAN_bFreePdoTxBuffer
Overflow_b

%IX101.0.4

Overflow of transmit
request memory

CAN_bFreePdoRxOverflo
w_b

%IX101.0.5

Overflow of receipt
memory

CAN_bOverrunLifeTime_
b

%IX101.0.6

"Node Life Time"
exceeded

CAN_byNodeAddress

Byte

˘

%IB101.2

C0350

˘

Node address
(CAN bus interface X4)

CAN_byState

%IB101.3

C0359

˘

CAN bus status
(CAN bus interface X4)

13.6.2

Outputs_CAN_Management

System variables

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Comments

CAN_bResetNode_b

BOOL

binary

%QX101.0.0

˘

˘

Carry out reset node
(CAN bus interface X4)

CAN_bTxCan2Synchroni
zed_b

%QX101.0.1

Transmit CAN2_OUT
with Sync telegram.

CAN_bTxCan3Synchroni
zed_b

%QX101.0.2

Transmit CAN3_OUT
with sync telegram.

Advertising