Commissioning – Lenze ECSCAxxx User Manual

Page 117

Advertising
background image

Commissioning

Setting of the feedback system for position and speed control

TTL/SinCos encoder as position and speed encoder

6

l

117

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

409

AM256−8V

(multi−turn)
Selections 407, 408, 409 are only
possible with operating system
7.0 or higher.

410

AM512−8V

411

AM1024−8V

[C0420] Encoder const.

512

Number of increments of the
encoder

^ 331

^ 115

^ 122

1

{1 inc/rev}

8192 Sets C0419 = 0 ("common") if the

value is altered.

[C0421] Encoder volt

0

Encoder voltage

^ 331

^ 115

^ 122

0

5.0 V

Sets C0419 = 0 ("common") if the
value is altered.

1

5.6 V

2

6.3 V

3

6.9 V

4

7.5 V

5

8.1 V

[C0427] Enc. signal

0

Function of the master frequency
input signals on X8 (DFIN)

^ 331

^ 115

^ 122

0

2−phase

1

A: speed
B: direction

2

A or B: speed or direction

[C0491] X8 in/out

0

Function of X8

^ 331

^ 115

^ 122

0

X8 is input

1

X8 is output

Advertising