Troubleshooting and fault elimination

Fault analysis
Fault analysis via the LED display

12

l

236

EDBCSXA064 EN 3.2

12

Troubleshooting and fault elimination

Failures can be quickly detected by means of display elements or status messages via the
system bus (CAN/CAN−AUX).

Display elements and status messages provide a rough classification of the trouble.

In the chapter "12.3.2 Causes and remedies" (

246) , you can find information on fault

elimination.

12.1

Fault analysis

12.1.1

Fault analysis via the LED display

LED

Operating state

Check

Red

Green

Off

On

Controller enabled, no fault

Off

Blinking

Controller inhibit (CINH) active, switch−on inhibit

C0183

Blinking

Off

Trouble/fault (TRIP) is active

C0168/1

Blinking

On

Warning/FAIL−QSP is active

C0168/1

12.1.2

Fault analysis with keypad XT EMZ9371BC

The status messages in the display indicate the controller status.

Display

Controller status

Check

RDY

Controller ready for operation, controller can be inhibited.

C0183, C0168/1

IMP

Pulses at the power stage inhibited.

C0183, C0168/1

Imax

Maximum current reached.

Mmax

Maximum torque reached.

FAIL

Fault through TRIP, message, fail QSP or warning.

C0183, C0168/1