3 access via system variables, Access via system variables, Preface and general information – Lenze ECSCAxxx User Manual

Page 23

Advertising
background image

Preface and general information

System block introduction

Access via system variables

1

l

23

EDBCSXA064 EN 3.2

1.5.3

Access via system variables

If you have integrated a system block into the system configuration of the DDS, you can use
its system variables within your project.

You can call up the input assistance in the editors of the DDS via <F2>, among other things
listing all the system variables that are provided:

In this Manual, the system variables can be retrieved in the system variable table of the
corresponding system block.

Example: Table with the inputs of the SB Inputs_Digital of the ECSxA... axis module

Variable

Data

type

Signal

type

Address

Display

code

Display

format

Notes

DIGIN_bCInh_b

BOOL

binary

%IX1.0.0

˘

˘

Controller inhibit ˘ takes
direct effect on the
device control DCTRL.

DIGIN_bIn1_b

%IX1.0.1

C0443

bin

DIGIN_bIn2_b

%IX1.0.2

DIGIN_bIn3_b

%IX1.0.3

DIGIN_bIn4_b

%IX1.0.4

DIGIN_b_safe_standstill_b

%IX1.0.5

"Safe torque off"
(former "safe standstill")