DCTRL_DriveControl (node number 121)

13

l

319

EDBCSXA064 EN 3.2

13.15

DCTRL_DriveControl (node number 121)

This FB controls the axis module into certain states:

ƒ

Quick stop (QSP,

^ 324)

ƒ

Operation inhibit (DISABLE,

^ 325)

ƒ

Controller inhibit (CINH,

^ 325)

ƒ

Setting a TRIP (TRIP−SET,

^ 326)

ƒ

Resetting a TRIP (TRIP−RESET,

^ 326)

C0150 displays the status of the axis module (

^ 239).

The process image is created in a permanent system task (interval: 2 ms).

)

Note!

The SB DCTRL_DriveControl only affects the motor control or the drive control.
Motor control/drive control and application program of the PLC are decoupled
from one another, provided that no query of the signals is effected in the
application program.

ƒ

If, for instance, a TRIP is activated by the motor control, the application
program thereby is not stopped!

ƒ

If, in contrast, a TRIP is activated as a result of a task overflow, the
application program of the PLC is stopped as well!