AIF_IO_Management (node number 161)

Inputs_AIF_Management

13

l

257

EDBCSXA064 EN 3.2

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0126 MONIT CE0

3

Fault response regarding the
monitoring of communication
via AIF interface X1.

l

Via C2382 you can select
whether controller inhibit
(CINH) or quick stop (QSP) is
activated when a CE0 fault
occurs.

^ 255

0

TRIP

A communication error activates
the CE0 response set.

2

Warning

3

Off

Monitoring switched off.

C2121 AIF:State

AIF status
More detailed information can
be found in the documentation
of the plugged−in fieldbus
module.
Read only

^ 195

1

{1}

255 Binary interpretation reflects bit

states.

Bit 0

XCAN1_IN monitoring time

Bit 1

XCAN2_IN monitoring time

Bit2

XCAN3_IN monitoring time

Bit3

XCAN bus off

Bit4

XCAN operational

Bit5

XCAN pre−operational

Bit 6

XCAN warning

Bit 7

Assigned internally