Code table

14

l

411

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C0540] X8 Signal out

2

Function of the digital frequency
output signals on X8 (DFOUT)

^ 112

0

DFOUT in [%]

1

DFOUT in [rpm]

2

Encoder simulation + zero pulse

®

DFOUT

C0545 PH offset

0

Phase offset

^ 340

0

{1 inc}

65535 1 revolution = 65535 increments

C0547 DIS: AN−IN

Analog signal on the input of the
DFOUT block
Read only

^ 340

−199.99

{0.00 %}

199.99

C0549 DIS: DF−IN

Speed on the input of the DFOUT
block
Only display

^ 340

−32767

{1 rpm}

32767

C0559 SD8 filter t

1

Filter time constant (SD8)

1

{1 ms}

200 Example:

If the setting is "10 ms", a
SD8−TRIP is actuated after 10 ms.

C0576 nErr tolerance

100

Tolerance window for the speed
system deviation referring to
n

max

100 % = lowest monitoring
sensitivity

^ 226

0

{1 %}

100

C0577 Vp fld weak

0.100

Gain of the field weakening
controller (V

p

)

^ 144

0.000

{0.001}

63.999

C0578 Tn fld weak

3.0

Integral−action time of the field
weakening controller (V

n

)

0.1

{0.1 ms}

6000.0

C0579 nErr response

3

Fault response − monitoring of
speed system deviation

^ 226

0

TRIP

1

Message

2

Warning

3

Off

4

FAIL−QSP

C0580 Monit SD8

3

Fault response − monitoring of
SinCos signals at X8

^ 225

0

TRIP

3

Off

C0581 MONIT EEr

0

Fault response − external fault
monitoring "ExternalFault" (EEr)

^ 326

0

TRIP

1

Message

2

Warning

3

Off

4

FAIL−QSP

Advertising