System modules

DFOUT_IO_DigitalFrequency (node number 22)

Inputs_DFOUT / Outputs_DFOUT

13

l

341

EDBCSXA064 EN 3.2

13.17.1.2

Configuration master frequency output signal

You configure the type of the master frequency output signal via C0540:

C0540 = 0

Output of an analog signal

Function

The input signal DFOUT_nOut_vis interpreted as an analog signal [%] and is output as a
frequency signal on the master frequency output X8.

Scaling

100 %

º (INT)16384 º C0011 (n

max)

Transmission
function

f [Hz]

+ DFOUT_nOut_v [%] @ C0030

100 @

C0011 (n

max

)

60

DFOUT_nln_v

+ f [Hz] @ 60

C0030 @

2

14

15000

Example

l

DFOUT_nOut_v = 50 %

l

C0030 = 3, this corresponds to a number of increments of 2048 increments/revolution

l

C0011 = 3000 rpm

f [Hz]

+ 50 % @ 2048

100 @

3000

60

+ 51200 Hz

C0540 = 1

Output of a speed signal

Function

The input signal DFOUT_nOut_vis interpreted as a speed signal [rpm] and is output as a
frequency signal on the master frequency output X8.

Scaling

15000 rpm

º (INT)16384

Transmission
function

f [Hz]

+ DFOUT_nOut_v [rpm] @ C0030

60

Example

l

DFOUT_nOut_v = 3000 rpm

l

C0030 = 3, this corresponds to a number of increments of 2048 increments/revolution

f [Hz]

+ 3000 rpm @ 2048

60

+ 102400 Hz

C0540 = 2

Encoder simulation of the resolver with zero track in resolver position

Function

l

The function is used if a resolver is connected to X7.

l

The encoder constant for output X8 is set in C0030.

l

The output of the zero pulse with reference to the rotor depends on how the resolver is
mounted to the motor.

l

The zero pulse can be shifted by +360 ° via C0545 (65536 inc = 360 °).

)

Note!

The zero pulse can only be output with C0540 = 2 (encoder simulation of
resolver).