Appendix – Lenze ECSCAxxx User Manual

Page 393

Advertising
background image

Appendix

Code table

14

l

393

EDBCSXA064 EN 3.2

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0135 Control word

0

System control word DCTRL

0

{1}

65535 Controller evaluates information

as 16 bits (binary−coded)

Bit 0

Not assigned

Bit 1

Not assigned

Bit 2

Not assigned

Bit 3

Quick stop (QSP)

Bit 4

Not assigned

Bit 5

Not assigned

Bit 6

Not assigned

Bit 7

Not assigned

Bit 8

Operation inhibit (DISABLE)

Bit 9

Controller inhibit (CINH)

Bit 10

TRIP−SET

Bit 11

TRIP−RESET

Bit 12

Not assigned

Bit 13

Not assigned

Bit 14

Not assigned

Bit 15

Not assigned

C0136

Control words
Hexadecimal value is bit−coded.
Read only

1 CTRLWORD

0

{hex}

FFFF Control word C0135

2 CTRLWORD

CAN control word

3 CTRLWORD

AIF control word

C0141 FCODE(setval)

0.0

Main setpoint (FCODE_C141_a)

^ 347

−199.99

{0.01 %}

199.99

C0142 Start options

1

Starting condition for start after

l

mains connection

l

message (t > 0.5 s)

l

TRIP

0

Protection against unexpected start−up

1

Automatic start