3 quick stop (qsp), System modules – Lenze ECSCAxxx User Manual

Page 324

Advertising
background image

System modules

DCTRL_DriveControl (node number 121)
Quick stop (QSP)

13

l

324

EDBCSXA064 EN 3.2

13.15.3

Quick stop (QSP)

The QSP function serves to stop the drive ˘ irrespective of the setpoint selection ˘ within
the time adjusted in C0105.

ƒ

The function can be controlled via the following inputs (OR’d):
– Control word DCTRL_wAIF1Ctrl (

259)

– Control word DCTRL_wCAN1Ctrl (

283)

– Control word C0135, bit 3

ƒ

C0136/1 indicates the control word C0135.

)

Note!

Quick stop (QSP) only is set if DCTRL_bQspIn_b is connected to
MCTRL_bQspOut_b of the SB MCTRL_MotorControl (

351)!

MCTRL_bQspOut_b

MCTRL_bNMSwt_b

MCTRL_nLoMLim_a

MCTRL_nHiMLim_a

C0907/3

C0906/4

C0906/3

C0907/2

OR

DCTRL_bQspIn_b

Any Variable

ECSXA267

Fig. 13−20

Programming: actuation of a quick stop (QSP) via SB "Inputs_DCTRL"

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0105 QSP Tif

0.0

Deceleration time for quick stop
(QSP)

^ 324

^ 361

0.000

{0.001 s}

999.999 Relating to speed variation n

max

(C0011) ...0 rev./min.

Advertising
This manual is related to the following products: