System program organisation units

14

l

383

EDBCSXA064 EN 3.2

14.4

System program organisation units

System POUs are program organisation units of the "program" type, which by means of a
specific designation adopt the feature of being started subject to an event occurring in the
ECSxA... axis module.

ƒ

The program includes max. 1000 instructions for system POUs.

ƒ

Unlike tasks or PLC_PRG, system POUs are not run−time monitored by a "watchdog".

ƒ

See the following table for special POU names and the related events for starting
the POU:

POU name

Event for starting POU

The POU starts if

PLC_TaskOverrun

Task overflow

... the task monitoring time is exceeded.

1)

PLC_RealError

Floating−point error

...a floating−point error occurs.

PLC_FailTripping

TRIP

...a trip is set.

PLC_WarningTripping

Warning

...a warning is activated.

PLC_MessageTripping

Message

...a message is indicated.

PLC_FailQspTripping

FAIL−QSP

...a FAIL−QSP is activated.

2)

PLC_CANError

CAN bus error

... a CAN bus error occurs (e.g. BUS−OFF).

3)

PLC_AIFError

AIF bus error

... an AIF bus error occurs.

3)

PLC_Restart

Start

... the START command is activated after a STOP.

PLC_ColdStart

Cold start

... a RESET, RESET (cold), RESET (original) or a program
download has been activated.

4)

Note: System variables must not be used in
PLC_ColdStart since this can lead to an unexpected
maloperation of the control system (e.g. restart of the
motor).

PLC_Stop

PLC stop

... the STOP command is activated.

5)

PLC_Undervoltage

LU threshold

... the set LU threshold is fallen below.

1)

The system variable "SYSTEM_bPLCResetAndRun"
does not execute a TRIP reset. Thus, an automatic
restart is not possible in this POU.
Procedure without mains switching:
PLC reset (C2108) => TRIP reset (C0043) => PLC start
(C2108)

2)

Is only called if pulse inhibit is not active.

3)

Only called if all monitoring functions of the
corresponding communication are deactivated.

4)

The CAN/AIF bus is ready after this POU has been
executed.

5)

This POU is not activated by Reset (cold, original).

I

Tip!

If you need a system POU for an event−controlled start, create a "program"
POU and use the name of this POU as POU name related to the corresponding
event listed in the table.