Aif interface (x1) configuration – Lenze ECSCAxxx User Manual

Page 194

Advertising
background image

AIF interface (X1) configuration

Monitoring

9

l

194

EDBCSXA064 EN 3.2

Codes for heartbeat

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/ap
pl.

Selection

C2369

0

XCAN Consumer Heartbeat
COB−ID
(AIF interface X1)

0

{1}

255

C2370

XCAN Heartbeat time setting
(AIF interface X1)

1

0

0

{1 ms}

65535 Consumer heartbeat time

2

0

0

{1 ms}

65535 Producer heartbeat time

Codes for emergency

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/ap
pl.

Selection

C2371

128

XCAN COB−ID Emergency Object
(AIF interface X1)

0

{1}

2047

C2372

0

XCAN COB−ID Emergency Object
(AIF interface X1)

0

{1}

65535 Inhibit time emergency

Advertising