12 canaux1_io (node number 34), System modules, Canaux1_io (node number 34) – Lenze ECSCAxxx User Manual

Page 303

Advertising
background image

System modules

CANaux1_IO (node number 34)

13

l

303

EDBCSXA064 EN 3.2

13.12

CANaux1_IO (node number 34)

This SB serves to transmit cyclic process data via the CAN bus interface X14.

A sync telegram which must be generated from another node is required for transmission.

ƒ

The transmission mode (event or time−controlled) is set via C2456.

ƒ

The monitoring time is set via C2457 (Lenze setting: 3000 ms).

CANaux1_nInW0_a

CANaux1_nInW1_a

CANaux1_bInB

_b

0...15

CANaux1_bInB

_b

16...31

Byte

7

8

5

6

3

4

1

2

Byte

7

8

5

6

3

4

1

2

CANaux1_nOutW0_a

CANaux1_nOutW1_a

CANaux1_nOutW2_a

CANaux1_bFDO

_b

16...31

CANaux1_dnOutD1_p

CANaux1_IO

DINT

WORD

WORD

WORD

16 x BOOL

DINT

Output user data

(8 bytes)

Input user data
(8 bytes)

L

H

L

H

CANaux1_bFDO

_b

0...15

16 x BOOL

CANaux1_nOutW3_a

WORD

CANaux1_nInW2_a

CANaux1_nInW3_a

CANaux1_dnInD1_p

C2493/1

C2493/2

C2493/3

CANaux1_bFDO

_b

32...47

16 x BOOL

CANaux1_bFDO

_b

48...63

16 x BOOL

WORD

WORD

16 x BOOL

16 x BOOL

WORD

C2492/1

C2492/2

C2492/3

16 x BOOL

16 x BOOL

WORD

C2491/1

CANaux1_bInB

_b

32...47

CANaux1_bInB

_b

48...63

C2491/2

X14

X14

Fig. 13−16

System block "CANaux1_IO"

Process data telegram

The process data telegram consists of an identifier and eight bytes of user data.

Identifier

8 bytes of user data

11 bits

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8