5 setting maximum speed, System modules – Lenze ECSCAxxx User Manual

Page 357

Advertising
background image

System modules

MCTRL_MotorControl (node number 131)

Setting maximum speed

13

l

357

EDBCSXA064 EN 3.2

13.20.5

Setting maximum speed

The maximum speed (n

max

) which is used as a reference variable for the absolute and

relative setpoint selection with regard to the acceleration and deceleration times as well
as to the upper and lower speed limit, is set via C0011.

ƒ

n

max

= 100 %

º (INT) 16384

)

Note!

MCTRL_nNmaxC11 displays the maximum speed set via C0011.

ƒ

By means of this system variable, you are able to program your own speed
scalings.

ƒ

Example: C0011 = 3000 rpm

ð MCTRL_nNmaxC11 = 3000

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0011 Nmax

3000

Maximum speed

^ 357

500

{1 rpm}

16000 Reference value for the absolute

and relative setpoint selection
for the acceleration and
deceleration times.
For parameter setting via
interface: greater changes in one
step should only be made when
the controller is inhibited (CINH)!