Rockwell Automation 284 ArmorStart User Manual User Manual

Page 115

Advertising
background image

Bulletin 283 Programmable Parameters

4-25

Zone #1 Offset

The byte offset into the ZIP data
portion of the DeviceLogix data
table to place the chosen
consumed data bytes for zone 1.

Parameter Number

82

Access Rule

GET/SET

Data Type

UINT

Group

ZIP Parameters

Units

MinimumValue

0

Maximum Value

7

Default Value

0

Zone #2 Offset

The byte offset into the ZIP data
portion of the DeviceLogix data
table to place the chosen
consumed data bytes for zone 2.

Parameter Number

83

Access Rule

GET/SET

Data Type

UNIT

Group

ZIP Parameters

Units

MinimumValue

0

Maximum Value

7

Default Value

0

Zone #3 Offset

The byte offset into the ZIP data
portion of the DeviceLogix data
table to place the chosen
consumed data bytes for zone 3.

Parameter Number

84

Access Rule

GET/SET

Data Type

UNIT

Group

ZIP Parameters

Units

MinimumValue

0

Maximum Value

1

Default Value

0

Zone #4 Offset

The byte offset into the ZIP data
portion of the DeviceLogix data
table to place the chosen
consumed data bytes for zone 4.

Parameter Number

85

Access Rule

GET/SET

Data Type

UNIT

Group

ZIP Parameters

Units

MinimumValue

0

Maximum Value

1

Default Value

0

Zone #1 EPR

The Expected Packet Rate in
msec. for the zone 1 consuming
connection. If consumed data is
not received in 4 times this value,
the zone connection will time out
and “Zone #1 Health” will report
1 = Not Healthy.

Parameter Number

86

Access Rule

GET/SET

Data Type

UINT

Group

ZIP Parameters

Units

msec

MinimumValue

0

Maximum Value

65535

Default Value

75