Bulletin 284 CIP Information

D-9

Bulletin 284 Distributed Motor Controller I/O Assemblies

Bulletin 284 Distributed Motor Controller IO Assemblies are
available ONLY on the Bulletin 284 Distributed Motor Controller.

Standard Distributed Motor Controller Output (Consumed)
Assemblies

Instance 164 is the default output (consumed) assembly for Inverter
Type Distributed Motor Controllers

Table D.24 Instance 164 — Default Consumed Inverter Type Distributed

Motor Controller.

Instance 166 is the standard output (consumed) assembly for Inverter
Type Distributed Motor Controllers with network inputs

Table D.25 Instance 166 — Consumed Inverter Type Starter with Network

Inputs

Standard Distributed Motor Controller Input (Produced)
Assemblies

Instance 52 is the required input (produced) assembly defined in the
DeviceNet Motor Starter Profile

Table D.26 Instance 52 — ODVA Starter.

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

User Out B

User Out A

Jog Rev

Jog

Fwd

Fault

Reset

Run Rev

Run

Fwd

1

Drive In 4

Drive In 3

Drive In 2

Drive In 1

Decel

2

Decel 1

Accel 2

Accel 1

2

Comm Frequency Command (Low) (xxx.x Hz)

3

Comm Frequency Command (High) (xxx.x Hz)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

User Out

B

User Out

A

Jog Rev

Jog Fwd

Fault

Reset

Run Rev

Run Fwd

1

Drive In

4

Drive In

3

Drive In

2

Drive In

1

Decel

2

Decel

1

Accel

2

Accel

1

2

Comm Frequency Command (Low) (xxx.x Hz)

3

Comm Frequency Command (High) (xxx.x Hz)

4

Net In 8

Net In 7

Net In 6

Net In 5

Net In 4

Net In 3

Net In 2

Net In 1

5

Net In 16 Net In 15 Net In 14 Net In 13

Net In 12 Net In 11 Net In 10

Net In 9

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Running

Fault