Bulletin 284 Programmable Parameters for Sensorless Vector Controllers

6-55

IR Voltage Drop
Value of volts dropped across the resistance of the motor stator.

Parameter Number

228

Related Parameters

227

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Program Group

Units

0.1V AC

Minimum Value

0.0

Maximum Value

230

Default Value

Based on Drive Rating

Flux Current Ref
Value of amps for full motor flux.

Parameter Number

229

Related Parameter

227

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Program Group

Units

0.01 A

Minimum Value

0.00

Maximum Value

Motor NP Volts

Default Value

Based on Drive Rating

PID Trim Hi
Sets the maximum positive value that is added to a PID reference when PID trim is
used.

Parameter Number

230

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Program Group

Units

0.1

Minimum Value

0.0

Maximum Value

400.0

Default Value

60.0

PID Trim Lo
Sets the minimum positive value that is added to a PID reference when PID trim is
used.

Parameter Number

231

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Program Group

Units

0.1

Minimum Value

0.0

Maximum Value

400.0

Default Value

0.1

PID Ref Select

Enables/disables PID mode and selects the source of the PID reference. Valid PID
Ref Select for the Bulletin 284 ArmorStart are the following:
0 = PID Disable
1 = PID Setpoint
4 = Comm Port
5 = Setpnt Trim
8 = Comm, Trim

Parameter Number

232

Related Parameters

138, 222

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Program Group

Units

Minimum Value

0

Maximum Value

9

Default Value

0

Stop drive before changing this parameter.