Rockwell Automation 284 ArmorStart User Manual User Manual

Page 387

Advertising
background image

Bulletin 283 CIP Information

C-15

Table C.33 Connection Object Instance 8-11 Attributes

The following services are implemented for the Connection Object:

Table C.34 Connection Objects Common Services

Attribute

ID

Access

Rule

Name

Data Type

Value

1

Get

State

USINT

0=nonexistant

1=configuring
3=established

2

Get

Instance Type

USINT

1=I/O Connection

3

Get

Transport Class Trigger

USINT

0x20 (COS,

unacknowledged)

4

Get

Produced Connection ID

UINT

FFFF (not producing data)

5

Get

Consumed Connection ID

UINT

01101xxxxxx

xxxxxx=node address

6

Get

Initial Comm Characteristics

USINT

0xF0 (unacknowledged)

7

Get

Produced Connection Size

UINT

0

8

Get

Consumed Connection Size

UINT

8

9

Get/Set

Expected Packet Rate

UINT

in milliseconds

12

Get

Watchdog Action

USINT

2=auto reset

13

Get

Produced Connection Path Length

UINT

0

14

Get

Produced Connection Path

0

15

Get

Consumed Connection Path Length

UINT

8

16

Get

Consumed Connection Path

21 0E 03 25 01 00 30 02

Service

Code

Implemented for:

Service

Name

Class

Instance

0x05

No

Yes

Reset

0x0E

No

Yes

Get_Attribute_Single

0x10

No

Yes

Set_Attribute_Single

Advertising