Step logic parameters – Rockwell Automation 284 ArmorStart User Manual User Manual

Page 477

Advertising
background image

Step Logic, Basic Logic and Timer/Counter Functions

J-5

Step Logic Parameters

Digit 3

Digit 2

Digit 1

Digit 0

0

0

F

1

Setting

Accel/Decel Parameters Used

Step Logic Output State

Commanded Direction

0

1

Off

FWD

1

1

Off

REV

2

1

Off

No Output

3

1

On

FWD

4

1

On

REV

5

1

On

No Output

6

2

Off

FWD

7

2

Off

REV

8

2

Off

No Output

9

2

On

FWD

A

2

On

REV

b

2

On

No Output

Setting

Logic

0

Jump to Step 0

1

Jump to Step 1

2

Jump to Step 2

3

Jump to Step 3

4

Jump to Step 4

5

Jump to Step 5

6

Jump to Step 6

7

Jump to Step 7

8

End Program (Normal Stop)

9

End Program (Coast to Stop)

A

End Program and Fault (F2)

Setting

Description

Logic

0

Skip Step (jump immediately).

SKIP

1

Step based on the time programmed in the respective (Stp Logic Time x) parameter.

TIMED

2

Step if Logic In1 is active (logically true).

TRUE

3

Step if Logic In2 is active (logically true).

TRUE

4

Step if Logic In1 is not active (logically false).

FALSE

5

Step if Logic In2 is not active (logically false).

FALSE

6

Step if either Logic In1 or Logic In2 is active (logically true).

OR

7

Step if both Logic In1 and Logic In2 is active (logically true).

AND

8

Step if neither Logic In1 or Logic In2 is active (logically true).

NOR