Rockwell Automation 284 ArmorStart User Manual User Manual

Page 233

Advertising
background image

Bulletin 284 Programmable Parameters for Sensorless Vector Controllers

6-59

Table 6.9

Digit 3 Settings

Table 6.10 Digit 2 Settings

Table 6.11

Digit 1 and Digit 0 Settings

Required

Setting

Accel/Decel

Parameter Used

Step Logic

Output State

Commanded

Direction

0

Accel/Decel 1

Off

FWD

1

Accel/Decel 1

Off

REV

2

Accel/Decel 1

Off

No Output

3

Accel/Decel 1

On

FWD

4

Accel/Decel 1

On

REV

5

Accel/Decel 1

On

No Output

6

Accel/Decel 2

Off

FWD

7

Accel/Decel 2

Off

REV

8

Accel/Decel 2

Off

No Output

9

Accel/Decel 2

On

FWD

A

Accel/Decel 2

On

REV

b

Accel/Decel 2

On

No Output

0

Jump to Step 0

1

Jump to Step 1

2

Jump to Step 2

3

Jump to Step 3

4

Jump to Step 4

5

Jump to Step 5

6

Jump to Step 6

7

Jump to Step 7

8

End Program (Normal Stop)

9

End Program (Coast to Stop)

A

End Program and Fault (F2)

0

Skip Step (Jump Immediately)

1

Step Based on (Stp Logic Time x)

2

Step if Logic In1 is Active

3

Step if Logic In2 is Active

4

Step if Logic In1 is Not Active

5

Step if Logic In12 is Not Active

6

Stop if either Logic In1 and Logic In2 is Active

7

Stop if both Logic In1 and Logic In2 is Active

8

Stop if neither Logic In1 and Logic In2 is Active

9

Step if Logic In1 is Active and Logic In2 is Not Active

A

Step if Logic In2 is Active and Logic In1 is Not Active

b

Step after (Stp Logic Time x) and Logic In1 is Active

C

Step after (Stp Logic Time x) and Logic In2 is Active

d

Step after (Stp Logic Time x) and Logic In1 is Not Active

E

Step after (Stp Logic Time x) and Logic In2 is Not Active

F

Do Not Stop/Ignore Digit 2 Settings