Diagnostics, Chapter – Rockwell Automation 284 ArmorStart User Manual User Manual

Page 291

Advertising
background image

Chapter

13

Diagnostics

Overview

This chapter describes the fault diagnostics of the ArmorStart®
Distributed Motor Controller and the conditions that cause various
faults to occur.

Protection Programming

Many of the protective features available with the ArmorStart
Distributed Motor Controller can be enabled and adjusted through the
programming parameters provided. For further details on
programming, refer to Chapter 3, 4, 5, or 6, Program and Status
Parameters.

Fault Display

The ArmorStart Distributed Motor Controller comes equipped with a
built-in LED status indication which provides four status LEDs and a
Reset button. The LEDs provide status indication for the following:

Power LED
The LED is illuminated solid green when control power is
present and with the proper polarity

RUN LED
This LED is illuminated solid green when a start command and
control power are present

Network LED
This bi-color (red/green) LED indicates the status of the
communication link

FAULT LED
Indicates Controller Fault (Trip) condition

The Reset Button provides local fault trip reset.

Figure 13.1 LED Status Indication and Reset

Important: Resetting the fault will not correct the cause of the fault

condition. Corrective action must be taken before
resetting the fault.

Advertising
This manual is related to the following products: