background image

B-4

Bulletin 280/281 CIP Information

DeviceNet Object — CLASS CODE
0x0003

The following class attributes are supported for the DeviceNet Object:

Table B.7 DeviceNet Object Class Attributes

A single instance (instance 1) of the DeviceNet Object is supported.
The following instance attributes are supported.

Table B.8 DeviceNet Object Instance Attributes

The following services are implemented for the DeviceNet Object:

Table B.9 DeviceNet Object Common Services

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

2

Attribute ID Access Rule

Name

Data Type

Value

1

Get/Set

Node Address

USINT

0 - 63

2 Get/Set

Baud

Rate

USINT

0=125K
1=250K
2=500K

3 = 1M ➊

5

Get

Allocation Info

Allocation Choice

Master Node Addr

Structure of:

BYTE

USINT

Allocation_byte*

0…63 = address

255 = unallocated

8

Get

MAC ID Switch Value

BOOL

0-63

1M baud is only available on the Bulletin 280A/281A.

*Allocation_byte

Bit 0

Explicit messaging

Bit 1

Polled I/O

Bit 4

COS I/O

Bit 5

Cyclic I/O

Bit 6

Acknowledge Suppression

Service

Code

Implemented for:

Service

Name

Class

Instance

0x0E

Yes

Yes

Get_Attribute_Single

0x10

No

Yes

Set_Attribute_Single

0x4B

No

Yes

Allocate_Master/Slave

_Connection_Set

0x4C

No

Yes

Release_Master/Slave

_Connection_Set

Advertising